Valid Values - Data Qualifiers



     
  
  

Export to Excel

Data Qualifier Code Data Qualifier Description Active
WLZ Well water level affected by other conditions. Y
WLX Well water level affected by nearby surface-water stage. Y
WLW Well was destroyed; water level could not be measured. Y
WLV LNAPL (floating product) or other foreign substance on well water. Y
WLT Nearby well(s) pumped recently. Y
WLS Nearby well(s) being pumped during measurement. Y
WLR Well site was pumped recently. Y
WLP Well site was being pumped during measurement. Y
WLO Well water level affected by/could not be measured due to obstruction in well. Y
WLN Well measurement discontinued. Y
WLM Well was plugged and not in hydraulic contact with the aquifer. Y
WLL Well water level affected by brackish or saline water. Y
WLK Water was cascading down inside of well. Y
WLJ Nearby well site(s) being injected during measurement. Y
WLI Well site was being injected during measurement. Y
WLH Nearby well(s) flowing recently. Y
WLG Nearby well(s) flowing during measurement. Y
WLF Well was flowing and could not be measured. Y
WLE Well was flowing recently. Y
WLD Well was dry during measurement attempt. Y
WLC Well water level affected by ice. Y
WLB Well water level affected by tidal stage. Y
WLA Well water level affected by atmospheric pressure. Y
VAR Variation within dataset; multiple results creating an unexpected pattern. Y
UJL Analyte was not detected at or above the reported estimate with likely high bias. Y
UJK Analyte was not detected at or above the reported estimate with unknown bias. Y
UJG Analyte was not detected at or above the reported estimate with likely low bias. Y
UJ Analyte was not detected at or above the reported estimate Y
U Analyte was not detected at or above the reported result. Y
T Reported result below associated quantitation limit but above MDL Y
REJ Data are unusable for all purposes. Sample results rejected due to serious deficiencies in the ability to analyze the sample and meet quality control criteria. The presence or absence of the analyte cannot be verified. Y
OUT Outlier within dataset; single result is unexpected or discontinuous. Y
OOR Out of range; dataset not in expected range for instrument type, data type, or historical climatology; reported result meets study objectives. Y
NUJ There is evidence the analyte is present in the sample. Tentatively identified analyte was not detected at or above the reported estimate. Y
NU There is evidence the analyte is present in the sample. Tentatively identified analyte was not detected at or above the reported result. Y
NJT There is evidence the analyte is present in the sample. Reported result for the tentatively identified analyte is an estimate below the associated quantitation limit but above the MDL. Y
NJ There is evidence that the analyte is present in the sample. Reported result for the tentatively identified analyte is an estimate . Y
N There is evidence the analyte is present in the sample. Tentatively identified analyte. Y
L Value is likely less than the reported result. Reported result may be biased high. Y
K Reported result with unknown bias. Y
JTL Analyte was positively identified. Value may be less than the reported result which is an estimate below associated quantitation limit but above MDL. Y
JTK Analyte was positively identified. Reported result is an estimate with unknown bias, below the associated quantitation limit but above the MDL. Y
JTG Analyte was positively identified. Value may be greater than the reported result, which is an estimate below the associated quantitation limit but above the MDL. Y
JT Analyte was positively identified. Reported result is an estimate below the associated quantitation limit but above the MDL. Y
JL Analyte was positively identified. Value may be less than the reported estimate. Y
JK Analyte was positively identified. Reported result is an estimate with unknown bias. Y
JG Analyte was positively identified. Value may be greater than the reported estimate. Y
J Analyte was positively identified. The reported result is an estimate. Y
IA Instrument result adjusted; reported result meets study objectives Y
G Value is likely greater than the reported result. Reported result may be biased low. Y
Page 1 of 2    <<-  <-    ->    -->>
63 records