Map facility     

A map with the facility/site. Continue on this page to hear information about where the facility/site is located.

Thermafiber LLC
2301 TAYLOR WAY TACOMA WA 98421-4304
GIS latitude:
47.26935
GIS longitude:
-122.38068
Ecology region:
SWRO
County:
Pierce
Location description:
Legislative district:
27
Congressional district:
9
WRIA:
10
Tribal land:
Y
Alternate names
Also known as
BILL WOOD USGI TACOMA PLANT
THERMAFIBER LLC
Thermafiber LLC Tacoma
USG PLANT SITE
Interactions for this facility/site
Interaction Interaction description Ecology program Ecology program contact Program ID Start date End date
Air Qual Oper Permit Source Facilities with actual or potential emissions that are greater than 100 tons of (or 10 tons any one hazardous air pollutants or 25 tons per year of a combination of hazardous pollutants) fugitive air emissions per year.  (These are generally large industrial facilities governed by the federal and state operating permit program.) See Ch. 173-401 WAC AIRQUAL (360) 407-6806
1/1/1977
Underground Storage Tank Any one or combination of tanks (including connecting underground pipes) that is used to contain regulated substances and has a tank volume of ten percent or more beneath the surface of the ground. This term does not include any of the exempt UST systems specified in WAC 173-360A-0110(1) or any piping connected thereto. See WAC 173-360A. TOXICS
tcphq_public_disclosure@ECY.WA.GOV
3464 12/15/1979 8/6/1996
Hazardous Waste Generator Facilities that generate any quantity of a dangerous waste.  They may be classified as SQG, MQG, or LQG depending on hazardous waste generated for a given month. HAZWASTE 800-874-2022
TurboWaste@ecy.wa.gov
WAD009242025 8/19/1980 10/31/2002
Emergency/Haz Chem Rpt TIER2 Businesses that store 10,000 pounds or more of a hazardous chemical or 500 pounds or less, depending on the chemical, of an extremely hazardous chemical on site at any one time must report annually. Reports are sent to the State Emergency Response Commission [represented by Ecology] Local Emergency Planning Committees, and local fire departments for emergency planning. [product, not waste] HAZWASTE (360) 407-6171
WAD009242025 1/1/1988 1/31/2003
LUST Facility A release related to a regulated leaking underground storage tank system is associated with the site. TOXICS
tcphq_public_disclosure@ECY.WA.GOV
3464 7/22/1998 8/24/1998
Toxics Release Inventory Facilities in specific industries that manufacture, process or use more than the threshold amount of one or more of 600 listed toxic chemicals. Most threshold amounts are 10,000 or 25,000 pounds per year. Some chemicals have much lower thresholds. HAZWASTE (360) 407-6171
WAD009242025 1/1/1999 12/31/2002
Hazardous Waste Planner Under Chapter 173-307 WAC, facilities that report under Section 313 of the Emergency Planning/Community Right-To-Know Act (EPCRA), or that generate more than 2,640 pounds of hazardous waste per year, must prepare Pollution Prevention Plans.  HAZWASTE (360) 999-3657
P2Plans@ecy.wa.gov
WAD009242025 1/1/2001 11/1/2002
Federal (Superfund) Cleanup St A federal cleanup site listed in CERCLIS where Ecology has been or is currently involved with the cleanup process or has knowledge of the site from another process. TOXICS
tcphq_public_disclosure@ECY.WA.GOV
1/1/1900
Enforcement Final An Enforcement action (i.e. Penalty, Order, Notice) was finalized and issued to the respective party, indicating the enforcement action was taken. The start and end date listed in the database are both the date the action was issued to the responsible party. TOXICS (360) 407-6712
6/26/2006
Industrial SW GP General permit issued to industries to regulate the discharge of contaminated stormwater to state waters. WATQUAL (360) 407-6400
SO3000305 12/28/1992 7/28/2003
NAICS codes for this facility
Code Description
327993 Mineral Wool Manufacturing
SIC codes for this facility
Code Description
3275 GYPSUM PRODUCTS
3296 MINERAL WOOL