Study ID | AMS005 |
Study Name | Continuous Stream Temperature Monitoring |
EIM Data Entry Review Status | Not Reviewed |
Study Type | General environmental study |
Study Purpose | Collect diel continuous water and air temperatures statewide at most of Ecology's Ambient Stream Monitoring Stations (June - September). The data may be used to evaluate compliance with state water quality standards and interpret a station's monthly temperature data. |
Field Collection Date Range | 6/4/2001 - 10/3/2019 |
Data First/Last Loaded Date | |
Data Last Updated Date | |
Ecology Program or Other Responsible Entity | Ecy Environmental Assessment Program |
Ecology Contact | Stephanie Estrella |
Ecology Monitoring Program | Freshwater Information Network (FIN) |
Submitting Organization | |
Study QA Planning Level | LEVEL 4: Approved QAPP or SAP. |
Study QA Project Plan Description | The accuracy of each temperature logger is verified through pre- and post-deployment calibration checks. Temperature loggers and a certified reference thermometer are tested in controlled water baths that bracket the expected monitoring range (near 0º C and near 20ºC). Field quality checks with a reference thermometer are done at deployments and retrievals; checks are done on a monthly basis for Ambient stations (Ambient QC checks are entered under Study ID AMS001-2). |
Study QA Assessment Level | Level 3: Data Verified and Assessed for Usability |
Study Result Description | Point temperature measurements recorded at 30 minute monitoring intervals. |
Study Comment | The stream water temperature data may have periods of data gaps caused by instrument malfunction or from the logger being exposed to air when flows drop below the deployment location. Data with gaps during the critical summer period may not represent seasonal maxima. |
Linked Study | |
Ecology Funding Number | |
Ecology Facility/Site ID | |
Ecology Cleanup Site ID | |
Recommended QC Blank Censor Factor | |
Study ID Aliases (Alias Type) | |