The Gas Company Spokane
Facility Site ID:
12751663
Cleanup Site ID:
17024
Cleanup Complete
The former gas station service bay floor drains and sump discharged to a drywell. The drywell was filled with sediment and sludge. Soil samples from the drywell showed that diesel and heavy-oil contamination required cleanup. About 1.82 tons of sediment and sludge were removed.
Soil around the drywell was excavated to 2 to 4 feet around the outsides of the drywell wall and about 5 feet below the base. Five confirmation soil samples were taken from all sides and under the drywell. Soil sample results show diesel and heavy-oil contamination to be below safe levels.
Ecology completed an initial investigation in April 2024 and decided no further cleanup was required in May.
Soil around the drywell was excavated to 2 to 4 feet around the outsides of the drywell wall and about 5 feet below the base. Five confirmation soil samples were taken from all sides and under the drywell. Soil sample results show diesel and heavy-oil contamination to be below safe levels.
Ecology completed an initial investigation in April 2024 and decided no further cleanup was required in May.
Documents 4
Legal 1
Document Title | Document Date | Document Type |
The Gas Company Spokane Drywell NFA | 5/7/2024 | NFA Opinion not under Ecology VCP or PLIA TAP |
Technical Reports 3
Document Title | Document Date | Document Type |
ERTS 730421 IIFR The Gas Company Drywell Spokane | 4/30/2024 | State Initial Investigation Report |
Soil Remediation at South Drywell and Additional Soil Sampling | 10/3/2023 | Site Specific Technical Document - Other |
Phase II Environmental Site Assessment | 3/1/2022 | Site Specific Technical Document - Other |
There may be more documents related to this site. To obtain documents not available electronically, you will need to make a public records request.
Places to see print documents
-
Eastern Regional OfficeN 4601 Monroe StSpokane, 99205-1265Please schedule an appointment to view print documents at this location.
Contaminants 2
Contaminant Type | Soil |
Groundwater |
Surface Water |
Air |
Sediment |
Bedrock |
---|---|---|---|---|---|---|
Non-Halogenated Organics - Petroleum-Diesel | RB | |||||
Non-Halogenated Organics - Petroleum-Other | RB |
- S
- Suspected
- C
- Confirmed Above Cleanup Levels
- B
- Below Cleanup Levels
- RA
- Remediated-Above
- RB
- Remediated-Below
- R
- Remediated
This contaminant list was based on our best information at the time it was entered. It may not reflect current conditions at the site.