Valid Values - Data Qualifiers



     
  
  

Export to Excel

Data Qualifier Code Data Qualifier Description Active
B Analyte detected in sample and method blank. Reported result is sample concentration without blank correction or associated quantitation limit. Y
B1 Analyte detected in sample and method blank. Reported result is blank-corrected. Y
E Reported result is an estimate because it exceeds the calibration range. Y
EQP Inconsistent equipment performance (sensor, instrument, etc.); reported result meets study objectives. Y
EST Measurement value reported is estimated. See comment for additional detail. Y
FA No site access Y
FD Site was dry Y
FE Equipment failure Y
FH Flow too high to measure Y
FI Ice impacted Y
FL Above or below instrument or method limit Y
FS Stagnant water - no flow Y
FT Flow tidally impacted Y
G Value is likely greater than the reported result. Reported result may be biased low. Y
IA Instrument result adjusted; reported result meets study objectives Y
J Analyte was positively identified. The reported result is an estimate. Y
JG Analyte was positively identified. Value may be greater than the reported estimate. Y
JK Analyte was positively identified. Reported result is an estimate with unknown bias. Y
JL Analyte was positively identified. Value may be less than the reported estimate. Y
JT Analyte was positively identified. Reported result is an estimate below the associated quantitation limit but above the MDL. Y
JTG Analyte was positively identified. Value may be greater than the reported result, which is an estimate below the associated quantitation limit but above the MDL. Y
JTK Analyte was positively identified. Reported result is an estimate with unknown bias, below the associated quantitation limit but above the MDL. Y
JTL Analyte was positively identified. Value may be less than the reported result which is an estimate below associated quantitation limit but above MDL. Y
K Reported result with unknown bias. Y
L Value is likely less than the reported result. Reported result may be biased high. Y
N There is evidence the analyte is present in the sample. Tentatively identified analyte. Y
NJ There is evidence that the analyte is present in the sample. Reported result for the tentatively identified analyte is an estimate . Y
NJT There is evidence the analyte is present in the sample. Reported result for the tentatively identified analyte is an estimate below the associated quantitation limit but above the MDL. Y
NU There is evidence the analyte is present in the sample. Tentatively identified analyte was not detected at or above the reported result. Y
NUJ There is evidence the analyte is present in the sample. Tentatively identified analyte was not detected at or above the reported estimate. Y
OOR Out of range; dataset not in expected range for instrument type, data type, or historical climatology; reported result meets study objectives. Y
OUT Outlier within dataset; single result is unexpected or discontinuous. Y
REJ Data are unusable for all purposes. Sample results rejected due to serious deficiencies in the ability to analyze the sample and meet quality control criteria. The presence or absence of the analyte cannot be verified. Y
T Reported result below associated quantitation limit but above MDL Y
U Analyte was not detected at or above the reported result. Y
UJ Analyte was not detected at or above the reported estimate Y
UJG Analyte was not detected at or above the reported estimate with likely low bias. Y
UJK Analyte was not detected at or above the reported estimate with unknown bias. Y
UJL Analyte was not detected at or above the reported estimate with likely high bias. Y
VAR Variation within dataset; multiple results creating an unexpected pattern. Y
WLA Well water level affected by atmospheric pressure. Y
WLB Well water level affected by tidal stage. Y
WLC Well water level affected by ice. Y
WLD Well was dry during measurement attempt. Y
WLE Well was flowing recently. Y
WLF Well was flowing and could not be measured. Y
WLG Nearby well(s) flowing during measurement. Y
WLH Nearby well(s) flowing recently. Y
WLI Well site was being injected during measurement. Y
WLJ Nearby well site(s) being injected during measurement. Y
Page 1 of 2    <<-  <-    ->    -->>
63 records