Category Code Description Source Reference Active Alias
Measurement pH-Ag/AgCl-Glass pH Sensor Using Pressure-Balanced Glass-Electrode with Ag/AgCl Reference Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field. Y
Measurement PARSensor-Sphere Sensor using a spherical silicon photovoltaic detector for measuring quantum response of photosynthetically active radiation (PAR) in 400-700 nm spectrum Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field. Y
Measurement DO-GALVANIC Dissolved Oxygen (DO) by Electrochemical Galvanic Cell Sensor Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field. Y
Measurement PARSensor-Vector Sensor using a plane (vector) silicon photovoltaic detector for measuring quantum response of photosynthetically active radiation (PAR) in 400-700 nm spectrum. Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field. Y
Measurement pH-SpectroPhoto-mCP pH by spectrophotometer and m-cresol purple (mCP) method. Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field. Y
Measurement DO-OPTICAL Dissolved Oxygen (DO) by Optical (Luminescent) Sensor (LDO) Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field. Y
Measurement TURB-NEPH-780 Turbidity by nephelometric field meter, 780 nm infrared light, 90 degree detector, 0-1600 NTU range Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field. Y
Measurement DO-CLARK-PULSE Dissolved Oxygen (DO) by Electrochemical Polarographic (Clark) Cell Sensor with Pulsing Membrane (Flow Independent) Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field. Y
Measurement TurbiditySeawater Turbidity by optical backscatter at 700nm with 124 degree detector Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field. Y
Measurement Pressure-StrainGauge Strain-gauge pressure sensor Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field. Y
Analysis Gordon-CFA-1993 Continuous Flow Automated Analysis (CFA) of Seawater Nutrients (Phosphate, Nitrate, Nitrite and Silicic Acid). Gordon, L., J. Jennings Jr, A. Ross, and J. Krest. 1993. A suggested protocol for continuous flow automated analysis of seawater nutrients (phosphate, nitrate, nitrite and silicic acid) in WOCE Hydrographic Program and Joint Global Ocean Fluxes Study. Y
Analysis GrossmanCarbon2009 Measurement of activated carbon and other black carbons in sediments. Grossman A, Ghosh U. Measurement of activated carbon and other black carbons in sediments. Chemosphere. 2009 Apr;75(4):469-75. Y
Analysis Gustafsson2001 Black carbon (BC) in marine sediments by chemothermal oxidation (CTO) method. Gustafsson, Ö., Bucheli, T. D., Kukulska, Z., Andersson, M., Largeau, C., Rouzaud, J.-N., Reddy, C. M., and Eglinton, T. I. ( 2001), Evaluation of a protocol for the quantification of black carbon in sediments, Global Biogeochem. Cycles, 15( 4), 881– 890 Y
Analysis Gustafsson1997A Quantification of the dilute sedimentary soot phase: Implications for PAH speciation and bioavailability. Gustafsson, O., F. Haghseta, C. Chan, J. Macfarlane, and P. Gschwend, M. 1997. Quantification of the dilute sedimentary soot phase: Implications for PAH speciation and bioavailability. Environ. Sci. Technol. 31:203-209. Y
ANALYSIS HACH-8226 Hardness, Total (as CaCO3), buret titration HACH Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com Y
Measurement HACH-8131 Sulfide in water by HACH 8131 field kit, Methylene Blue Method, adapted from Standard Methods 4500S2D Hach Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com Y
MEASUREMENT HACH-CL8P Chloride by HACH 8-P field kit, silver nitrate drop count titration Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com Y
MEASUREMENT HACH-NI14 Nitrogen, Nitrate As NO3 by HACH field kit NI-14, Color disc/Cadmium reduction Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com Y
Measurement HACH-IR-18C Iron, ferrous (Fe2+), in Water by Color Disc/1,10 Phenanthroline Test Kit. Hach Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com Y
Measurement HACH-AL-AP-MG/L Alkalinity By Drop Count Titration/Sulfuric Acid, Test Kit Model AL-AP, mg/L, Product #2444301. Hach Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com Y
Measurement HACH-8146 Iron, Ferrous, in water by HACH 8146 field kit, 1,10 Phenanthroline Method, Powder Pillows or AccuVac Ampuls, adapted from Standard Methods SM3500FeB Hach Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com Y
MEASUREMENT HACH-MN-5 Manganese by HACH MN-5 Field Kit, Color Disc/Cold Periodate Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com Y
Analysis HACH-10360-1.1 Luminescence Measurement of Dissolved Oxygen in Water and Wastewater and for Use in the Determination of five-day biochemical oxygen demand (BOD-5) and carbonaceous BOD-5. Revision 1.1, January 2006 Hach Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com, Revision 1.1, January 2006 Y
Analysis HACH-10360-1.2 Luminescence Measurement of Dissolved Oxygen in Water and Wastewater and for Use in the Determination of five-day biochemical oxygen demand (BOD-5) and carbonaceous BOD-5. Revision 1.2, October 2011 Hach Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com, Revision 1.2, October 2011 Y
Measurement HACH-8008 Iron, Total, in water by HACH 8008 FerroVer 1,10-Phenanthroline Method. Hach Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com. Y
ANALYSIS HANSEN99 Determination of Nutrients (Ammonia, Nitrate, Nitrite, Phosphate, Silicate, etc) in Seawater by Automated Analysis, HP Hansen and F Koroleff, 1999 (in Methods of Seawater Analysis, K Klaus et al, Ed., 3rd Ed) Hansen, HP, and F Koroleff, 1999. Determination of Nutrients by Automated Analysis. In: K. Grasshoff et al. (Ed.) Methods of Seawater Analysis, 3rd Ed, pp 208-223. Wiley-VCH, 632 p ISBN 3-527-29589-5 Y
ANALYSIS DO-WT-GRASSHOFF99 Dissolved oxygen (DO) by Winkler titration modified per Hansen/Grasshoff, Ehrhardt, and Kremling (1999). Hanson, H.P., 1999. Determination of Oxygen. IN: Methods of Seawater Analysis, K. Grasshoff, K. Kremling, and M Ehrhardt, Third ed., WILEY-VCH Verlag GmbH, Germany. Pp 75-89. Y
Derivation TDS-CALC-HEM85 Total Dissolved Solids (TDS), Calculated, Hem 1985 Hem, J.D., 1985, Study and interpretation of the chemical characteristics of natural water (3rd Ed.): USGS Water Supply Paper 2254. Y
Analysis EPA515 Determination of Chlorinated Herbicides in Drinking Water by Gas Chromatography (CG) with an Electron Capture Detector, Revision 2.0 USEPA Hodgeson, JW, 1986. Determination of Chlorinated Herbicides in Drinking Water, EPA-615R86002. Supplement to Methods for the Determination of Organic Compounds in Finished Drinking Water and Raw Source Water. Other revisions of the same method: EPA-NPS-3 Y
ANALYSIS Holme1971 Grain Size Distribution by Sieve-Pipette, Holme and McIntyre, 1971 Holme, N.A. and A. D. McIntyre, 1971, Methods for the study of marine benthos, IBP hand-book no. 16. Blackwell Scientific Publications, Oxford, 334 p. Y
Analysis EPASOP-EMAB114.0 Improved Method for the Extraction and Analysis of Perfluorinated Compounds (PFCs) from Surface Waters and Well Water by Ultra-High Performance Liquid Chromatography (UPLC)-Tandem Mass Spectrometry (MS/MS). USEPA Human Exposure and Atmospheric Sciences Division, National Exposure Research Laboratory, Office of Research and Development, USEPA, March 13, 2009. Y
ANALYSIS IDEXX-Enterolert IDEXX Laboratories Enterolert Test Kit Procedure for Enterococci in Water IDEXX IDEXX Laboratories, One IDEXX Drive, Westbrook, ME 04092, 1-800-321-0207, www.idexx.com, Revision 1999 Y
ANALYSIS IKONOMOU02 Gas Chromatography - High Resolution Mass Spectrometry (GC-HRMS) Based Method for the Simultaneous Determination of Nine Organotin Compounds in Water, Sediment, and Tissue Ikonomou, M.G., M. Fernandez, T. He, and D.A. Cullon. 2002. Journal of Chromatography A, 975(2):319-333. Y
Analysis EPA524.2 Puregable Organic Compounds in Water by Capillary Column by Gas Chromatography/Mass Spectrometry (GC/MS) USEPA IN EPA Methods and Guidance for Analysis of Water, Version 2.0, Method Revision 4.1, 1995 Y
MEASUREMENT ITI455 Innerspace Technology 455 single frequency survey depth sounder (accuracy of 0.2 m with 0.1 m measurement resolution) Innerspace Technology, Inc., Carlstadt, N.J., (201) 933-1600, http://www.innerspacetechnology.com Y
Derivation INT-PED-SW-EPA1668C In Situ Determination of Surface Water Polychlorinated Biphenyls (PCBs) Using Polyethylene Device (PED) Passive Sampler Deployed for 30 Days, Analyzed by EPA 1668C (Chlorinated Biphenyls in Water, Soil, Sediment, Biosolids and Tissue by HRGC/HRMS, Revision C), and Equilibrium Corrected Based on Performance Reference Compounds (PRC). Integral Consulting Inc. Based on Gschwend P, MacFarlane J, Palaia K, Reichenbacher S, Gouveia D. 2012. Passive PE Sampling in Support of In Situ Remediation of Contaminated Sediments. ESTCP Project ER-200915, Version 1, December 2012. Y
Derivation INT-LB16-EPA1668C Ex Situ Determination of Porewater Polychlorinated Biphenyls (PCBs) in Field-Collected Sediment Using Polyethylene Device (PED) Passive Sampler, Shaken for 30 Days in Lab, Analyzed by EPA 1668C (Chlorinated Biphenyls in Water, Soil, Sediment, Biosolids and Tissue by HRGC/HRMS, Revision C), and Equilibrium Corrected Based on Performance Reference Compounds (PRC). Integral Consulting Inc. October 2017. SOP-LB-16. Based on USEPA/SERDP/ESTCP. 2017. Laboratory, Field, and Analytical Procedures for using Passive Sampling in the Evaluation of Contaminated Sediments: User's Manual. EPA/600/R-16/357. Y
Derivation INT-LB17-AXYS-MLA021 Ex Situ Determination of Porewater Polycyclic Aromatic Hydrocarbons (PAHs) in Field-Collected Sediment Using Polyethylene Device (PED) Passive Sampler, Shaken for 30 Days in Lab, Analyzed by AXYS MLA-021 Rev 12 (PAH, Alkylated PAH and Alkanes in Sediment, Tissue, Water Hexane Extracts, XAD Resin and Filter Samples by GC/MS), and Equilibrium Corrected Based on Performance Reference Compounds (PRC). Integral Consulting Inc. September 2017. SOP-LB-17. Based on USEPA/SERDP/ESTCP. 2017. Laboratory, Field, and Analytical Procedures for using Passive Sampling in the Evaluation of Contaminated Sediments: User's Manual. EPA/600/R-16/357. Y
Analysis ISO-13320:2009 Particle/grain size distribution by laser diffraction for solid and liquid matrices ISO 13320:2009, Particle Size Analysis – Laser Diffraction Methods, International Organization for Standardization, Geneva, Switzerland, Corrected version 2009-12-01 Y
Measurement ISO-7027-1:2016A Turbidity by Nephelometry (part 1A) ISO 7027-1:2016, Water quality, Determination of turbidity, Part 1: Quantitative methods, ISO/TC 147/SC 2, Physical, chemical and biochemical methods, 13.060.60, Examination of physical properties of water Y
Analysis Carter2011-DI-IRMS Dual-inlet isotope ratio mass spectrometry (DI-IRMS) J. F. Carter and V. J. Barwick (Eds), Good practice guide for isotope ratio mass spectrometry, FIRMS (2011). ISBN 978-0-948926-31-0. Y
ANALYSIS JIANG96 Speciation Analysis of Organotin and Organogermanium Compounds by On-column Capillary Gas Chromatography with Flame Photometric Detection using Quartz Surface-Induced Luminescene Jiang, G.B. et al. 1996. Journal of Chromatography A, 727, pp. 119-129. Y
Analysis EPA-KAHN88 Lloyd Kahn Method for Determination of Total Organic Carbon (TOC) in Sediment. USEPA Kahn, Lloyd, 1988. Determination of Total Organic Carbon in Sediment. US EPA Region II Environmental Services Division, Edison, NJ, July 27, 1988. Y
ANALYSIS KEIL2009 Analysis of Cooking Spices in Natural Waters by Gas Chromatography/Mass Spectrometry (GC/MS) and Selective Ion Monitoring (SIM) Keil R., and Neibauer J., 2009, Limnology and Oceanography Methods, 7: 848-855. Y
ANALYSIS KEROUEL1997 Fluorometric determination of ammonia in sea and estuarine waters by direct segmented flow analysis Kerouel, R, and Alain Aminot. Marine Chemistry, Volume 57, Issues 3-4, July 1997, Pages 265-275 Y
ANALYSIS KCEL-SOP457 Anatoxin-a by High Performance Liquid Chromatography with Fluorescence Detector (HPLC-FD) King County Environmental Lab, Aquatic Toxicology Section, Seattle, WA, Draft SOP 457, 2009. Y
Analysis KCEL-SOP466 Anatoxin-a by High Performance Liquid Chromatography with Tandem Mass Spectrometry Detection (HPLC-MS/MS) King County Environmental Lab, Aquatic Toxicology Section, Seattle, WA, SOP 466, 2013 Y
Analysis KCEL-SOP563 Bacteroides in Environmental Waters by Membrane Filtration and qPCR King County Environmental Lab, Microbiology Unit, Seattle, WA, SOP 563, 2013 Y
Analysis KCEL-SOP7085 Per- and Polyfluoroalkyl Substances (PFAS) in Tissue by High Performance Liquid Chromatography with Tandem Mass Spectrometry Detection (HPLC-MS/MS). King County Environmental Lab, Organics Unit, Seattle, WA, SOP 7085, 2021 Y
Analysis KCEL-SOP781 Brominated Diphenyl Ethers in Water Soil, Sediment and Tissue by GC/MS-NCI (negative chemical ionization). King County Environmental Lab, Organics Unit, Seattle, WA, SOP 781, 2015 Y