Category |
Code |
Description |
Source |
Reference |
Active
|
Alias
|
MEASUREMENT
|
BIOHabitatMetric018
|
Number of taxa representing Ephemeroptera, Plecoptera, and Trichoptera within the sample
|
|
|
Y
|
|
Collection
|
PassDiffAirRadial
|
Passive Diffusive Radiello (Radial-Style) Air Sampler
|
|
|
Y
|
|
Collection
|
Niskin-ProgramClose
|
Bottle, Niskin, programmed prior to deployment to auto-trigger closure at target (nominal) depth, based on pressure sensor measurement. Closure depth recorded by data logger and post-processed.
|
|
|
Y
|
|
COLLECTION
|
AUGER-CME
|
Auger, CME (Central Mine Equipment) hollow stem
|
|
|
Y
|
|
COLLECTION
|
GOFLOW-TEF
|
Bottle, GoFlow, Teflon lined
|
|
|
Y
|
|
Preparation
|
FILTER.80um
|
Water sample filtered with 0.80 micron (micrometer) filter (material unspecified)
|
|
|
Y
|
FILTER.80M
|
PREPARATION
|
SIEVE-4.75MM
|
Sieved with 4.75 millimeter screen
|
|
|
Y
|
|
Collection
|
DirectPushSplitSpoon
|
Direct Push (like Geoprobe) with split spoon sampler
|
|
|
Y
|
|
Preservation
|
HgCl-Freeze-4DegC
|
Sample preserved with mercury chloride (HgCl) and frozen at -4 degree Celsius
|
|
|
Y
|
|
COLLECTION
|
D-FRAMEKICKNET500UM
|
Benthic macroinvertebrate collection by D-frame kick with 1x1 ft mouth and 500 um mesh net
|
|
|
Y
|
|
ANALYSIS
|
TURB-LNRM
|
Turbidity, nephelometric, lab non-ratio meter (white light, 90 deg detector only)
|
|
|
Y
|
|
COLLECTION
|
AUGER-STM
|
Auger, steam
|
|
|
Y
|
|
Measurement
|
SWF-VIS-EST
|
Streamflow by visual estimate
|
|
|
Y
|
|
COLLECTION
|
COMP-SED-BACTERIA
|
Composite of bacteria sediment samples collected from a transect or grid cell by scooping with stainless steel spoon into stainless steel bowl, then thoroughly stirring to homogenize. Collection and decontamination procedures follow Ecology SOP EAP069.
|
|
|
Y
|
|
MEASUREMENT
|
DEPTH
|
Depth by measuring stick or tape
|
|
|
Y
|
|
MEASUREMENT
|
BIOHabitatMetric010
|
The percent of the sample made up of organisms that consume fine particulate organic matter, and include both Gatherers (those who collect from the bottom substrate) and Filterers (those who collect from the water column)
|
|
|
Y
|
|
Measurement
|
Transmissometer
|
Underwater beam transmittance by photoelectric transmissometer, wavelength 650-60 nm, pathlength 25 cm.
|
|
|
Y
|
|
Collection
|
AugerSplitSpoon
|
Auger, hollow stem with split spoon sampler
|
|
|
Y
|
Auger-SplitSpoon
|
Collection
|
BAILER-POLYETHYLENE
|
Bailer, Polyethylene
|
|
|
Y
|
|
COLLECTION
|
VANVEEN.60
|
Grab sampler, Van Veen, 0.60 m2
|
|
|
Y
|
|
Derivation
|
PCALC-365.1-4500P-F
|
Total Phosphorus calculated by adding Phosphorus by EPA365.1 (Phosphorus, All Forms (Colorimetric, Automated, Ascorbic Acid)) and Phosphorus by SM4500PF (Phosphorus/Orthophosphate by Automated Ascorbic Acid Reduction).
|
|
|
Y
|
|
Measurement
|
PHSTRIP
|
pH by strip
|
|
|
Y
|
|
COLLECTION
|
CORE-KB-M
|
Corer, Modified K-B
|
|
|
Y
|
|
Derivation
|
EPA353.2-ASTM-D3590
|
Total Nitrogen calculated from Nitrate-Nitrite as N by EPA353.2 and Total Kjeldahl Nitrogen as N by ASTM-D3590.
|
|
|
Y
|
|
Measurement
|
GWL-TAPE-PASTE
|
Product or groundwater level by measuring tape with hydrocarbon- and water-sensitive paste
|
|
|
Y
|
TAPE-PASTE
|
Collection
|
SPME-LIQUID-INSITU
|
Solid Phase Microextraction (SPME) fiber sampler for liquids, deployed in situ.
|
|
|
Y
|
|
COLLECTION
|
KEMMER-SS
|
Bottle, Kemmerer, Stainless Steel
|
|
|
Y
|
|
MEASUREMENT
|
BIOHabitatMetric047
|
Measures diversity by reporting the chance that any two randomly drawn individuals from a sample are the same species. This measure is heavily influenced by relative abundance of each taxa. The measure scores between 0 and 1, with a more diverse community reflected by a score close to 1.
|
|
|
Y
|
|
Measurement
|
SWFMB
|
Streamflow by bucket or other container and stopwatch.
|
|
|
Y
|
|
Measurement
|
IFGA-METER
|
Infrared Dual Wavelength Internal Cell Gas Analyzer/Field Meter (for percent CH4, CO2, O2)
|
|
|
Y
|
IGA-METER
|
COLLECTION
|
CORE-SHLBY
|
Corer, Shelby tube
|
|
|
Y
|
|
MEASUREMENT
|
BIOHabitatMetric037
|
The ratio of organsims that feed on attached periphyton (Scrapers) to the number of organisms that feed by filtering organic matter from the water column (Filterers).
|
|
|
Y
|
|
MEASUREMENT
|
BIOHabitatMetric008
|
Percent of the taxa in the sample that survive in a narrow range of cold water temperatures
|
|
|
Y
|
|
Collection
|
Multiprobe
|
Collected using multi-parameter probe
|
|
|
Y
|
|
Collection
|
SPME-LIQUID-EXSITU
|
Solid-Phase Microextraction (SPME) fiber sampler for liquids, ex situ (in lab using field sample).
|
|
|
Y
|
|
PREPARATION
|
SIEVE-0.063MM
|
Sieved with 0.063 millimeter screen
|
|
|
Y
|
|
Collection
|
BAILER-UNKNOWN
|
Bailer, material unknown
|
|
|
Y
|
|
MEASUREMENT
|
BIOHabitatMetric003
|
Ratio of Baetidae/Ephemeroptera within the sample
|
|
|
Y
|
|
Collection
|
CRABPOT
|
Captured by crab pot.
|
|
|
Y
|
|
MEASUREMENT
|
PYRANOMETR
|
Solar radiation by portable Pyranometer
|
|
|
Y
|
|
MEASUREMENT
|
BIOHabitatMetric020
|
The percent of the sample made up of organisms that consume fine particulate organic matter collected from the water column
|
|
|
Y
|
|
MEASUREMENT
|
BIOHabitatMetric053
|
Number of taxa in the sample that produces a single generation per year
|
|
|
Y
|
|
Measurement
|
ISE-NH4
|
Ion-Selective Electrode Probe for Field Measurement of Ammonium Ions in Water
|
|
|
Y
|
|
Analysis
|
TBE-CS137-2007
|
Cs-137 Radiochemistry, Teledyne-Brown Engineering SOP, based on EPA 901.1 (Gamma Radiation Detection)
|
|
|
Y
|
|
Collection
|
INSITU-SPE
|
Active Integrative Sampler with In Situ Solid Phase Extraction (SPE) disk or cartridge.
|
|
|
Y
|
|
MEASUREMENT
|
TURB-FRM
|
Turbidity, nephelometric, field ratio meter (white light, 90 deg detector w/correction detectors)
|
|
|
Y
|
|
MEASUREMENT
|
BIOHabitatMetric007
|
The number of taxa in the sample represented by organisms that have adaptations to help them attach to surfaces in flowing water.
|
|
|
Y
|
|
PREPARATION
|
DECANT
|
Decant
|
|
|
Y
|
|
MEASUREMENT
|
TURB-FNRM
|
Turbidity, nephelometric, field non-ratio meter (white light, 90 deg detector only)
|
|
|
Y
|
|
MEASUREMENT
|
BIOHabitatMetric009
|
Number of taxa in the sample that survive in a narrow range of cold water temperatures
|
|
|
Y
|
|
1504 records
|