Category |
Code |
Description |
Source |
Reference |
Active
|
Alias
|
ANALYSIS
|
KRONE89
|
Butyltins in Sediment and Tissue, Krone et al., 1989
|
Ecology-MEL
|
Krone, C.A., D.W. Brown, D.G. Burrows, R.G. Bogar, S.-L. Chan and U. Varanasi, 1989. A method for analysis of butyltin species and the measurement of butyltins in sediment and English sole livers from Puget Sound. Marine Environmental Research, 27:1-18.
|
Y
|
|
ANALYSIS
|
KOLPIN01-3
|
Pharmaceuticals in Wastewater by Solid Phase Extraction (SPE) with HPLC-MS and Selected Ion Monitoring (SIM)
|
|
Kolpin, D.W., et al., 2002. Pharmaceuticals, Hormones, and Other Organic Wastewater Contaminants
in U.S. Streams, 1999 – 2000: A National Reconnaissance. Environmental Science and
Technology 36:1202-1211. Method 3.
|
Y
|
|
Analysis
|
JGOFS94-CH8
|
The Determination of Nitrite, Nitrate +Nitrite, Orthophosphate and Reactive Silicate in Seawater using continuous Flow Analysis.
|
|
Knap, A., A. Michaels, A. Close, H. Ducklow and A. Dickson (eds.). 1996. Protocols for the Joint Global Ocean Flux Study (JGOFS) Core Measurements. JGOFS Report Nr. 19, vi+170 pp. Reprint of the IOC Manuals and Guides No. 29, UNESCO 1994.
|
Y
|
|
Analysis
|
KECL-SOP740V1
|
Lipids by Pulsed Sonication, King County Environmental Lab SOP
|
|
King County Environmental Lab, Seattle WA. Standard Operation Procedure 740V1, 12/21/2006.
|
Y
|
KCSOP740V1
|
Analysis
|
KCEL-SOP781
|
Brominated Diphenyl Ethers in Water Soil, Sediment and Tissue by GC/MS-NCI (negative chemical ionization).
|
|
King County Environmental Lab, Organics Unit, Seattle, WA, SOP 781, 2015
|
Y
|
|
Analysis
|
KCEL-SOP7085
|
Per- and Polyfluoroalkyl Substances (PFAS) in Tissue by High Performance Liquid Chromatography with Tandem Mass Spectrometry Detection (HPLC-MS/MS).
|
|
King County Environmental Lab, Organics Unit, Seattle, WA, SOP 7085, 2021
|
Y
|
|
Analysis
|
KCEL-SOP563
|
Bacteroides in Environmental Waters by Membrane Filtration and qPCR
|
|
King County Environmental Lab, Microbiology Unit, Seattle, WA, SOP 563, 2013
|
Y
|
|
Analysis
|
KCEL-SOP466
|
Anatoxin-a by High Performance Liquid Chromatography with Tandem Mass Spectrometry Detection (HPLC-MS/MS)
|
|
King County Environmental Lab, Aquatic Toxicology Section, Seattle, WA, SOP 466, 2013
|
Y
|
|
ANALYSIS
|
KCEL-SOP457
|
Anatoxin-a by High Performance Liquid Chromatography with Fluorescence Detector (HPLC-FD)
|
|
King County Environmental Lab, Aquatic Toxicology Section, Seattle, WA, Draft SOP 457, 2009.
|
Y
|
|
ANALYSIS
|
KEROUEL1997
|
Fluorometric determination of ammonia in sea and estuarine waters by direct segmented flow analysis
|
|
Kerouel, R, and Alain Aminot. Marine Chemistry, Volume 57, Issues 3-4, July 1997, Pages 265-275
|
Y
|
|
ANALYSIS
|
KEIL2009
|
Analysis of Cooking Spices in Natural Waters by Gas Chromatography/Mass Spectrometry (GC/MS) and Selective Ion Monitoring (SIM)
|
|
Keil R., and Neibauer J., 2009, Limnology and Oceanography Methods, 7: 848-855.
|
Y
|
|
Analysis
|
EPA-KAHN88
|
Lloyd Kahn Method for Determination of Total Organic Carbon (TOC) in Sediment.
|
USEPA
|
Kahn, Lloyd, 1988. Determination of Total Organic Carbon in Sediment. US EPA Region II Environmental Services Division, Edison, NJ, July 27, 1988.
|
Y
|
|
ANALYSIS
|
JIANG96
|
Speciation Analysis of Organotin and Organogermanium Compounds by On-column Capillary Gas Chromatography with Flame Photometric Detection using Quartz Surface-Induced Luminescene
|
|
Jiang, G.B. et al. 1996. Journal of Chromatography A, 727, pp. 119-129.
|
Y
|
|
Analysis
|
Carter2011-DI-IRMS
|
Dual-inlet isotope ratio mass spectrometry (DI-IRMS)
|
|
J. F. Carter and V. J. Barwick (Eds), Good practice guide for isotope ratio mass spectrometry, FIRMS (2011). ISBN 978-0-948926-31-0.
|
Y
|
|
Measurement
|
ISO-7027-1:2016A
|
Turbidity by Nephelometry (part 1A)
|
|
ISO 7027-1:2016, Water quality, Determination of turbidity, Part 1: Quantitative methods, ISO/TC 147/SC 2, Physical, chemical and biochemical methods, 13.060.60, Examination of physical properties of water
|
Y
|
|
Analysis
|
ISO-13320:2009
|
Particle/grain size distribution by laser diffraction for solid and liquid matrices
|
|
ISO 13320:2009, Particle Size Analysis – Laser Diffraction Methods, International Organization for Standardization, Geneva, Switzerland, Corrected version 2009-12-01
|
Y
|
|
Derivation
|
INT-LB17-AXYS-MLA021
|
Ex Situ Determination of Porewater Polycyclic Aromatic Hydrocarbons (PAHs) in Field-Collected Sediment Using Polyethylene Device (PED) Passive Sampler, Shaken for 30 Days in Lab, Analyzed by AXYS MLA-021 Rev 12 (PAH, Alkylated PAH and Alkanes in Sediment, Tissue, Water Hexane Extracts, XAD Resin and Filter Samples by GC/MS), and Equilibrium Corrected Based on Performance Reference Compounds (PRC).
|
|
Integral Consulting Inc. September 2017. SOP-LB-17. Based on USEPA/SERDP/ESTCP. 2017. Laboratory, Field, and Analytical Procedures for using Passive Sampling in the Evaluation of Contaminated Sediments: User's Manual. EPA/600/R-16/357.
|
Y
|
|
Derivation
|
INT-LB16-EPA1668C
|
Ex Situ Determination of Porewater Polychlorinated Biphenyls (PCBs) in Field-Collected Sediment Using Polyethylene Device (PED) Passive Sampler, Shaken for 30 Days in Lab, Analyzed by EPA 1668C (Chlorinated Biphenyls in Water, Soil, Sediment, Biosolids and Tissue by HRGC/HRMS, Revision C), and Equilibrium Corrected Based on Performance Reference Compounds (PRC).
|
|
Integral Consulting Inc. October 2017. SOP-LB-16. Based on USEPA/SERDP/ESTCP. 2017. Laboratory, Field, and Analytical Procedures for using Passive Sampling in the Evaluation of Contaminated Sediments: User's Manual. EPA/600/R-16/357.
|
Y
|
|
Derivation
|
INT-PED-SW-EPA1668C
|
In Situ Determination of Surface Water Polychlorinated Biphenyls (PCBs) Using Polyethylene Device (PED) Passive Sampler Deployed for 30 Days, Analyzed by EPA 1668C (Chlorinated Biphenyls in Water, Soil, Sediment, Biosolids and Tissue by HRGC/HRMS, Revision C), and Equilibrium Corrected Based on Performance Reference Compounds (PRC).
|
|
Integral Consulting Inc. Based on Gschwend P, MacFarlane J, Palaia K, Reichenbacher S, Gouveia D. 2012. Passive PE Sampling in Support of In Situ Remediation of Contaminated Sediments. ESTCP Project ER-200915, Version 1, December 2012.
|
Y
|
|
MEASUREMENT
|
ITI455
|
Innerspace Technology 455 single frequency survey depth sounder (accuracy of 0.2 m with 0.1 m measurement resolution)
|
|
Innerspace Technology, Inc., Carlstadt, N.J., (201) 933-1600, http://www.innerspacetechnology.com
|
Y
|
|
Analysis
|
EPA524.2
|
Puregable Organic Compounds in Water by Capillary Column by Gas Chromatography/Mass Spectrometry (GC/MS)
|
USEPA
|
IN EPA Methods and Guidance for Analysis of Water, Version 2.0, Method Revision 4.1, 1995
|
Y
|
|
ANALYSIS
|
IKONOMOU02
|
Gas Chromatography - High Resolution Mass Spectrometry (GC-HRMS) Based Method for the Simultaneous Determination of Nine Organotin Compounds in Water, Sediment, and Tissue
|
|
Ikonomou, M.G., M. Fernandez, T. He, and D.A. Cullon. 2002. Journal of Chromatography A, 975(2):319-333.
|
Y
|
|
ANALYSIS
|
IDEXX-Enterolert
|
IDEXX Laboratories Enterolert Test Kit Procedure for Enterococci in Water
|
IDEXX
|
IDEXX Laboratories, One IDEXX Drive, Westbrook, ME 04092, 1-800-321-0207, www.idexx.com, Revision 1999
|
Y
|
|
Analysis
|
EPASOP-EMAB114.0
|
Improved Method for the Extraction and Analysis of Perfluorinated Compounds (PFCs) from Surface Waters and Well Water by Ultra-High Performance Liquid Chromatography (UPLC)-Tandem Mass Spectrometry (MS/MS).
|
USEPA
|
Human Exposure and Atmospheric Sciences Division, National Exposure Research Laboratory, Office of Research and Development, USEPA, March 13, 2009.
|
Y
|
|
ANALYSIS
|
Holme1971
|
Grain Size Distribution by Sieve-Pipette, Holme and McIntyre, 1971
|
|
Holme, N.A. and A. D. McIntyre, 1971, Methods for the study of marine benthos, IBP hand-book no. 16. Blackwell Scientific Publications, Oxford, 334 p.
|
Y
|
|
Analysis
|
EPA515
|
Determination of Chlorinated Herbicides in Drinking Water by Gas Chromatography (CG) with an Electron Capture Detector, Revision 2.0
|
USEPA
|
Hodgeson, JW, 1986. Determination of Chlorinated Herbicides in Drinking Water, EPA-615R86002. Supplement to Methods for the Determination of Organic Compounds in Finished Drinking Water and Raw Source Water. Other revisions of the same method: EPA-NPS-3
|
Y
|
|
Derivation
|
TDS-CALC-HEM85
|
Total Dissolved Solids (TDS), Calculated, Hem 1985
|
|
Hem, J.D., 1985, Study and interpretation of the chemical characteristics of natural water (3rd Ed.): USGS Water Supply Paper 2254.
|
Y
|
|
ANALYSIS
|
DO-WT-GRASSHOFF99
|
Dissolved oxygen (DO) by Winkler titration modified per Hansen/Grasshoff, Ehrhardt, and Kremling (1999).
|
|
Hanson, H.P., 1999. Determination of Oxygen. IN: Methods of Seawater Analysis, K. Grasshoff, K. Kremling, and M Ehrhardt, Third ed., WILEY-VCH Verlag GmbH, Germany. Pp 75-89.
|
Y
|
|
ANALYSIS
|
HANSEN99
|
Determination of Nutrients (Ammonia, Nitrate, Nitrite, Phosphate, Silicate, etc) in Seawater by Automated Analysis, HP Hansen and F Koroleff, 1999 (in Methods of Seawater Analysis, K Klaus et al, Ed., 3rd Ed)
|
|
Hansen, HP, and F Koroleff, 1999. Determination of Nutrients by Automated Analysis. In: K. Grasshoff et al. (Ed.) Methods of Seawater Analysis, 3rd Ed, pp 208-223. Wiley-VCH, 632 p ISBN 3-527-29589-5
|
Y
|
|
Measurement
|
HACH-8008
|
Iron, Total, in water by HACH 8008 FerroVer 1,10-Phenanthroline Method.
|
Hach
|
Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com.
|
Y
|
|
Analysis
|
HACH-10360-1.2
|
Luminescence Measurement of Dissolved Oxygen in Water and Wastewater and for Use in the Determination of five-day biochemical oxygen demand (BOD-5) and carbonaceous BOD-5. Revision 1.2, October 2011
|
Hach
|
Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com, Revision 1.2, October 2011
|
Y
|
|
Analysis
|
HACH-10360-1.1
|
Luminescence Measurement of Dissolved Oxygen in Water and Wastewater and for Use in the Determination of five-day biochemical oxygen demand (BOD-5) and carbonaceous BOD-5. Revision 1.1, January 2006
|
Hach
|
Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com, Revision 1.1, January 2006
|
Y
|
|
ANALYSIS
|
HACH-8226
|
Hardness, Total (as CaCO3), buret titration
|
HACH
|
Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com
|
Y
|
|
Measurement
|
HACH-8131
|
Sulfide in water by HACH 8131 field kit, Methylene Blue Method, adapted from Standard Methods 4500S2D
|
Hach
|
Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com
|
Y
|
|
MEASUREMENT
|
HACH-CL8P
|
Chloride by HACH 8-P field kit, silver nitrate drop count titration
|
|
Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com
|
Y
|
|
MEASUREMENT
|
HACH-NI14
|
Nitrogen, Nitrate As NO3 by HACH field kit NI-14, Color disc/Cadmium reduction
|
|
Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com
|
Y
|
|
Measurement
|
HACH-IR-18C
|
Iron, ferrous (Fe2+), in Water by Color Disc/1,10 Phenanthroline Test Kit.
|
Hach
|
Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com
|
Y
|
|
Measurement
|
HACH-AL-AP-MG/L
|
Alkalinity By Drop Count Titration/Sulfuric Acid, Test Kit Model AL-AP, mg/L, Product #2444301.
|
Hach
|
Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com
|
Y
|
|
Measurement
|
HACH-8146
|
Iron, Ferrous, in water by HACH 8146 field kit, 1,10 Phenanthroline Method, Powder Pillows or AccuVac Ampuls, adapted from Standard Methods SM3500FeB
|
Hach
|
Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com
|
Y
|
|
MEASUREMENT
|
HACH-MN-5
|
Manganese by HACH MN-5 Field Kit, Color Disc/Cold Periodate
|
|
Hach Company, P.O. Box 389. Loveland, Colorado, 80539-0389, 800-227-4224, http://www.hach.com
|
Y
|
|
Analysis
|
Gustafsson1997A
|
Quantification of the dilute sedimentary soot phase: Implications for PAH speciation and bioavailability.
|
|
Gustafsson, O., F. Haghseta, C. Chan, J. Macfarlane, and P. Gschwend, M. 1997. Quantification of the dilute sedimentary soot phase: Implications for PAH speciation and bioavailability. Environ. Sci. Technol. 31:203-209.
|
Y
|
|
Analysis
|
Gustafsson2001
|
Black carbon (BC) in marine sediments by chemothermal oxidation (CTO) method.
|
|
Gustafsson, Ö., Bucheli, T. D., Kukulska, Z., Andersson, M., Largeau, C., Rouzaud, J.-N., Reddy, C. M., and Eglinton, T. I. ( 2001), Evaluation of a protocol for the quantification of black carbon in sediments, Global Biogeochem. Cycles, 15( 4), 881– 890
|
Y
|
|
Analysis
|
GrossmanCarbon2009
|
Measurement of activated carbon and other black carbons in sediments.
|
|
Grossman A, Ghosh U. Measurement of activated carbon and other black carbons in sediments. Chemosphere. 2009 Apr;75(4):469-75.
|
Y
|
|
Analysis
|
Gordon-CFA-1993
|
Continuous Flow Automated Analysis (CFA) of Seawater Nutrients (Phosphate, Nitrate, Nitrite and Silicic Acid).
|
|
Gordon, L., J. Jennings Jr, A. Ross, and J. Krest. 1993. A suggested protocol for continuous flow automated analysis of seawater nutrients (phosphate, nitrate, nitrite and silicic acid) in WOCE Hydrographic Program and Joint Global Ocean Fluxes Study.
|
Y
|
|
Measurement
|
TEMPTHERM
|
Temperature by thermistor
|
|
Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field.
|
Y
|
|
Measurement
|
FLUOROMETER-OP
|
Open path fluorometric optical sensor for Chlorophyll, Colored Dissolved Organic Matter (CDOM), Uranine (fluorescein), Rhodamine, Phycoerythrin, and Phycocyanin fluorescence.
|
|
Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field.
|
Y
|
|
Analysis
|
DIC-NDIR
|
Dissolved Inorganic Carbon (DIC) by Analyzer With Non-Dispersive Infrared (NDIR) CO2 Detection.
|
|
Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field.
|
Y
|
|
Derivation
|
BeamAttenCalc
|
Light beam attenuation coefficient in water column, calculated from transmissometer measurements, wavelength 650 to 660 nm, pathlength 25 cm
|
|
Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field.
|
Y
|
|
Measurement
|
Pressure-DigiQuartz
|
Digital quartz pressure sensor
|
|
Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field.
|
Y
|
|
Measurement
|
DO-NonInvOpticalSpot
|
Dissolved Oxygen (DO) by Non-Invasive Optical Sensor Spot/Patch.
|
|
Generic, technology-based method. Use in place of instrument-specific methods. If you wish, put instrument-specific info in comment field.
|
Y
|
|
1504 records
|